Double Disc Check Valve
Product Description
The double disc check valve is a one-way valve, also known as double door check valve, double flap check valve or double plate check valve. It allows fluid to flow in one direction and cannot flow in the other direction. Check valves of various sizes, shapes and types are available, and they are usually self-adjusting, meaning that the flow of fluid itself often controls the opening and closing of the check valve. The disc of the check valve opens under the action of fluid pressure, and the fluid flows from the inlet side to the outlet side. When the pressure on the inlet side is lower than that on the outlet side, the valve disc will automatically close under the action of fluid pressure difference, gravity and other factors to prevent the fluid from flowing back.
The double door or dual plate check valve features a disc divided in two along a center line. The two doors can hinge open to allow forward flow or arrest backflow. Compact and lightweight, this type of check valve is often implemented for low-pressure liquid and gas applications.
Double plate check valve is mainly composed of important parts such as valve body, valve plate, valve stem and spring. The valve is mainly installed in water supply system, high-rise buildings and industrial plants. Because its surface spacing is shorter than that of general check valves, it is especially suitable for installation in compact spaces.
Features of double disc check valve
Wafer connection, compact structure;
The inner parts are made of stainless steel and have a long service life.
Midline structure, short structure length, small size and light weight.
The flow channel is smooth and the fluid resistance is small.
The valve disc is spring loaded, and the torsion spring realizes quick closing, which can effectively reduce the water hammer pressure.
The sealing performance is good, the closing is noiseless, and it can meet the requirements of zero leakage.
Easy installation, both horizontal and vertical pipes can be used.
Product Standards of double disc check valve
Connection standard: GB/T17241.6
Structure length standard: GB/T12221
Inspection and test standard: GB/T13927
technical parameter
Nominal diameter: DN50~DN600 (2"~24")
Nominal pressure: PN10/16
Operating temperature: 0°C~85°C
Sealing test: 1.1PN
Shell test: 1.5PN
According to the structure, check valves can be divided into three types: lift check valves, swing check valves and butterfly check valves. Lift check valve can be divided into vertical and horizontal. The swing check valve is divided into three types: single-lobe, double-lobe and multi-lobe. The butterfly check valve is a straight-through type. The above types of check valves can be divided into three types: threaded connection, flange connection and welding.
Common faults and troubleshooting methods
Fault phenomenon | Reason | Exclude |
Sealing surface leakage | 1. There are pollutants attached to the sealing surface | 1. Remove dirt |
2. The sealing surface is damaged | 2. Rework and trim the sealing surface. If the welding layer of the sealing surface is not enough, re-surfacing or replace the valve seat | |
3. The sealing surface is worn out after long-term use | 3. Re-surfacing the sealing surface or replace the valve seat | |
The handwheel is inflexible or the gate cannot be opened and closed | 1. Uneven tightening of connecting bolts | 1. Tighten the bolts evenly |
2. Damaged flange sealing surface | 2. Refinish | |
3. Cracked or failed gasket | 3. Replace the gasket |
Hot Tags: double disc check valve, China double disc check valve manufacturers, suppliers, factory, valves for chemical industry, check valve for sewer line, gas tank vent check valve, umbrella check valve, counter weight check valve, forged steel lift check valve